Wir verwenden Cookies, um für diese Website Funktionen wie z.B. Login, einen Warenkorb oder die Sprachwahl zu ermöglichen. Weiterhin nutzen wir für anonymisierte, statistische Auswertungen der Nutzung Google Analytics, welches Cookies setzt. Mehr Informationen finden Sie in unserer Datenschutzerklärung.
OK, ich bin einverstanden Ich möchte keine Google Analytics-Cookies
International Journal of Oral Implantology
Login:
Benutzername:

Kennwort:

Plattform:

Kennwort vergessen?

Registrieren

Int J Oral Implantol (Berl) 8 (2015), Nr. 4     7. Dez. 2015
Int J Oral Implantol (Berl) 8 (2015), Nr. 4  (07.12.2015)

Seite 387-396, PubMed:26669548, Sprache: Englisch


Immediately loaded machined versus rough surface dental implants in edentulous jaws: One-year postloading results of a pilot randomised controlled trial
Esposito, Marco / Felice, Pietro / Barausse, Carlo / Pistilli, Roberto / Grandi, Giovanni / Simion, Massimo
Purpose: To compare the effectiveness of immediately loaded total prostheses supported by implants with a roughened surface versus implants with a machined/turned surface.
Materials and methods: Fifty edentulous or to-be-rendered edentulous patients requiring an implant-supported cross-arch prosthesis, were randomised either to receive four to eight implants with a roughened surface (25 patients) or with a machined/turned surface (25 patients). Provisional metal-reinforced acrylic prostheses were delivered 48 h after implant placement. Provisional prostheses were replaced after 4 months, by definitive screw-retained metal-resin cross-arch restorations. Outcome measures were prosthesis and implant failures, any complications and peri-implant marginal bone level changes. Patients were followed 1 year after loading.
Results: One year after loading no patient dropped out. No prosthesis failed, but two machined implants were found to be mobile at definitive impression taking in 1 patient (Fisher's exact test: P = 0.312; difference in proportions = 4%; 95% Cl: -10 to 18). No complications occurred. Both groups presented a significant peri-implant marginal bone loss at 1 year after loading (P < 0.0001), -0.64 ± 0.20 mm for rough implants and -0.68 ± 0.23 mm for turned implants, respectively, with no statistically significant differences between the two groups (P = 0.482; mean difference = 0.04 mm; 95% Cl: -0.17 to 0.25).
Conclusions: Up to 1 year after immediate loading, both implant surfaces provided good and similar results, however, the only two implants which failed early in the same patient had a machined surface. These preliminary results must be confirmed by larger trials with longer follow-ups.

Schlagwörter: full edentulism, immediately loaded machined dental implants, roughened dental implants